AayulLab, for laboratories & scan centres
From Sample, to a Result in the Record.
Results verified under your policy and published as structured data into the patient's record, where the next doctor compares them with last time.
A test catalogue with panels and your own prices. Orders from doctors, the front desk and the marketplace. Specimens accessioned with their chain of custody. Results entered by hand or straight from the analyser, checked against reference ranges by age and sex, verified under your policy, and published as structured data into the patient's record, where the next doctor compares them with last time.
- SpecimenBarcode LB-4821-01 · accessionedchain keptcollected at the desk, 09:04
- HbA1c7.9 %Hfrom the analyser through the Lab Bridge
- Range4.0 to 5.6 %, by age and sexflagged automatically
- StatusPending verificationtwo-stageyour policy for this test
- Analyser
- Results in through the Lab Bridge
- By age & sex
- Reference ranges, flagged automatically
- Your policy
- Two-stage verification or auto-verify
- Structured
- Into the record, compared visit to visit
Why It Pays.
Fewer phone calls about results
A verified result lands in the patient's record and in the ordering doctor's review list. Critical values are acknowledged, not chased.
Less typing from the analyser
The Lab Bridge takes results straight from the machine, maps its codes to your catalogue, and shows what failed to land.
Your policy, enforced
Two-stage verification or auto-verify within a delta, turnaround targets per test, and an amendment trail.
New orders without a sales visit
Clinics pick preferred labs; the marketplace lists your slots and home-collection setting to families nearby.
An Order, Sample to Record.
Each moment is something the platform does today.
- 09:04
Order in, payment cleared
From the clinic, the desk or a marketplace booking, cleared before processing or waived by you.
- 09:12
Specimen accessioned
Barcoded, its events logged, on the section's worklist.
- 11:40
The analyser answers
Through the Lab Bridge, codes mapped to your catalogue, checked against ranges by age and sex.
- 12:05
Verified and published
Under your policy. A structured result in the record and on the doctor's review list.
What You Get.
Four parts, and everything in them that is in the build today. Anything not yet built is named as coming soon.
Test catalogue & orders (LIS)
Tests, panels, prices; orders from clinics, desk and marketplace
- Test catalogue
Panels, reference ranges, per-lab pricing
- Orders in
From consultations, the front desk, ward rounds and marketplace bookings
- Payment clearance
Paid before processing, with a waiver when you say so
- Marketplace listing
Public slots, booking hours, home-collection setting, plan and onboarding
Every Analyser the Bridge Has a Profile For.
58 profiles, by section.A profile holds the protocol, the port or serial settings, and the map from the analyser's test codes to the catalogue. Each is confirmed on the laboratory's own unit at installation; codes, units and ports are editable per instrument.
Biochemistry
| Maker | Models | Protocol | Connection |
|---|---|---|---|
| Erba (Transasia) | XL-200 / XL-640 / XL-1000 | ASTM / LIS2-A2 | Serial, TCP |
| Roche | cobas c 111 / c 311 / c 501 | ASTM / LIS2-A2 | Serial, TCP |
| Mindray | BS-240 / BS-480 / BS-800 | HL7 v2 (MLLP) | TCP |
| Beckman Coulter | AU480 / AU680 / DxC 700 AU (ASTM mode) | ASTM / LIS2-A2 | Serial, TCP |
| Beckman Coulter | AU 480 / 680 / 5800 (online format) | Fixed-width records | Serial, TCP |
| Siemens Healthineers | Dimension EXL / RxL / Atellica CH | ASTM / LIS2-A2 | Serial, TCP |
| Abbott | ARCHITECT c4000 / c8000 / ci4100 | ASTM / LIS2-A2 | Serial, TCP |
| Abbott | Alinity c / i (IHE LAW) | HL7 v2 (MLLP) | TCP |
| Ortho Clinical Diagnostics | VITROS 250 / 350 / 4600 / 5600 | ASTM / LIS2-A2 | Serial, TCP |
| Roche | cobas pro / cobas c 303 / c 503 | ASTM / LIS2-A2 | Serial, TCP |
| Transasia (Erba) | EM 200 / EM 360 / XL-180 | ASTM / LIS2-A2 | Serial, TCP |
| Dirui | CS-T240 / CS-400 / CS-600 | ASTM / LIS2-A2 | Serial, TCP |
| Any | Semi-automatic chemistry analyser with a printer port (Erba Chem 5/7, Robonik, Transasia Merilyzer…) | Serial printout | Serial |
| Bio-Rad | D-10 / VARIANT II / VARIANT II TURBO | ASTM / LIS2-A2 | Serial, TCP |
| Tosoh | HLC-723 G8 / G11 | ASTM / LIS2-A2 | Serial, TCP |
| Roche | 9180 electrolyte analyser (printout) | Serial printout | Serial |
| Medica | EasyLyte Na/K/Cl (printout) | Serial printout | Serial |
| Radiometer | ABL80 / ABL90 FLEX / ABL800 | ASTM / LIS2-A2 | Serial, TCP |
| Siemens Healthineers | RAPIDPoint 500 / RAPIDLab 1200 | ASTM / LIS2-A2 | Serial, TCP |
| Abbott | i-STAT (results exported from its data manager) | File export (CSV) | File |
| Any | Point-of-care device (POCT1-A) | POCT1-A | TCP |
Clinical pathology
| Maker | Models | Protocol | Connection |
|---|---|---|---|
| Sysmex | UF-1000i / UF-4000 / UC-3500 | ASTM / LIS2-A2 | Serial, TCP |
| Siemens Healthineers | CLINITEK Status / Advantus (printout) | Serial printout | Serial |
| Dirui | H-500 / H-800 urine analyser (printout) | Serial printout | Serial |
Haematology
| Maker | Models | Protocol | Connection |
|---|---|---|---|
| Sysmex | XN series (XN-L 350/450/550, XN-1000) | ASTM / LIS2-A2 | Serial, TCP |
| Sysmex | XP-100 / XP-300 (3-part) | ASTM / LIS2-A2 | Serial, TCP |
| Mindray | BC-5000 / BC-5150 / BC-6200 (5-part) | HL7 v2 (MLLP) | TCP |
| Sysmex | XS-800i / XS-1000i | ASTM / LIS2-A2 | Serial, TCP |
| Sysmex | KX-21 / KX-21N / pocH-100i (printout) | Serial printout | Serial |
| Mindray | BC-20s / BC-30s / BC-3000 (3-part) | HL7 v2 (MLLP) | TCP |
| Mindray | BC-2800 / BC-2300 (printout) | Serial printout | Serial |
| Horiba | Yumizen H500 / H550 / H1500 | ASTM / LIS2-A2 | Serial, TCP |
| Horiba | Micros ES60 / Pentra ES60 / ABX Micros 60 | ASTM / LIS2-A2 | Serial, TCP |
| Erba (Transasia) | H360 / H560 / Elite 3 | ASTM / LIS2-A2 | Serial, TCP |
| Beckman Coulter | DxH 500 / 800 / 900 | ASTM / LIS2-A2 | Serial, TCP |
| Abbott | CELL-DYN Ruby / Emerald / Alinity h | ASTM / LIS2-A2 | Serial, TCP |
| Nihon Kohden | Celltac MEK-6510 / MEK-7300 | Serial printout | Serial |
| Dymind | DH36 / DF50 | HL7 v2 (MLLP) | TCP |
| Stago | STA Compact Max / STA Satellite / STA R Max | ASTM / LIS2-A2 | Serial, TCP |
| Sysmex | CS-1600 / CS-2500 / CA-600 | ASTM / LIS2-A2 | Serial, TCP |
| Erba (Transasia) | ECL 105 / 412 / 760 | ASTM / LIS2-A2 | Serial, TCP |
Immunoassay
| Maker | Models | Protocol | Connection |
|---|---|---|---|
| Roche | cobas e 411 / e 601 | ASTM / LIS2-A2 | Serial, TCP |
| Abbott | ARCHITECT i1000SR / i2000SR | ASTM / LIS2-A2 | Serial, TCP |
| Siemens Healthineers | ADVIA Centaur XP / CP / Atellica IM | ASTM / LIS2-A2 | Serial, TCP |
| Beckman Coulter | Access 2 / DxI 600 / 800 | ASTM / LIS2-A2 | Serial, TCP |
| Snibe | MAGLUMI 800 / 2000 / X3 / X8 | ASTM / LIS2-A2 | Serial, TCP |
| Mindray | CL-900i / CL-1000i / CL-2000i | HL7 v2 (MLLP) | TCP |
| Tosoh | AIA-360 / AIA-900 | ASTM / LIS2-A2 | Serial, TCP |
| bioMérieux | VIDAS / mini VIDAS | ASTM / LIS2-A2 | Serial, TCP |
Microbiology
| Maker | Models | Protocol | Connection |
|---|---|---|---|
| bioMérieux | VITEK 2 Compact / BacT/ALERT 3D | ASTM / LIS2-A2 | Serial, TCP |
| BD | BACTEC FX / Phoenix M50 | ASTM / LIS2-A2 | Serial, TCP |
Serology
| Maker | Models | Protocol | Connection |
|---|---|---|---|
| Any | ELISA plate reader (export to file) | File export (CSV) | File |
Any section
| Maker | Models | Protocol | Connection |
|---|---|---|---|
| Any | Other ASTM (LIS2-A2) analyser | ASTM / LIS2-A2 | Serial, TCP |
| Any | Analyser following IHE LAW (HL7 2.5.1: QBP^Q11, OML^O33, OUL^R22) | HL7 v2 (MLLP) | TCP |
| Any | Other HL7 v2 analyser | HL7 v2 (MLLP) | TCP |
| Any | Other analyser that prints its results (serial printout) | Serial printout | Serial, TCP |
| Any | Other analyser that exports results to a file (CSV) | File export (CSV) | File |
| Any | Other analyser that sends fixed-width records | Fixed-width records | Serial, TCP |
Scanners connect over DICOM through the same bridge: modality worklist, exam status, image receive and forward to the archive. ECGs arrive as files.
Who Uses It.
Each person signs in to the surface and permissions their job needs, on the same record.
- Tests, panels, prices
- Verification and auto-verify policy
- Analyser setup and code maps
- Turnaround settings, staff, plan
- Pending collection lists
- Barcode and label
- Chain-of-custody events
- Ward-round collection
- Worklist per section
- Results by hand or from the analyser
- Quality control
- Validate for verification
- Verify, reject, amend
- Critical alerts
- Report signature
- Published into the record
A verified result is structured data in the patient's record, not a file. The next doctor sees it beside the previous value.
Laboratories and scan centres: Pricing.
One plan each for a standalone laboratory and a standalone scan centre.
- Catalogue, orders, samples, results, reports
- Analyser connections
- Billing and marketplace bookings
- 10 staff seats, 50 GB
- WhatsApp from your own number
- 15-day trial once Aayul has verified you
- Walk-ins, worklist, reporting and signing
- Picture archive and the scanners' worklist
- 10 staff seats, 50 GB
- WhatsApp from your own number
- 15-day trial once Aayul has verified you
Offer prices are for your first year; the struck-out price applies from the second year. Prices read from the platform's published price lists on 2026-11-16. Prices in INR. Plans for every role are on the pricing page.
Questions People Ask.
Is this a LIS, and does it interface with analysers?
Yes. Catalogue, orders, accessioning, worklists, verification and reporting are the LIS. The Lab Bridge connects analysers over ASTM, HL7, serial printout, file export or POCT1-A, and scanners over DICOM, with profiles for 58 analyser families confirmed on your own unit at installation.
Which analysers connect?
Any that the Lab Bridge can reach on your network. Each analyser's codes are mapped to your catalogue once; quality control runs stay with it.
Can doctors outside AayulHealth order from us?
Orders come from clinics on the platform, the front desk, ward rounds and marketplace bookings. A paper order is entered at the desk.
Is there a scan centre edition?
Yes. Scan Centre One covers the modality worklist, studies with dose, verified reports, PACS and the viewer, peer review and the Form F register.
Signed Reports.
Results verified under your policy and published as structured data into the patient's record, where the next doctor compares them with last time.